{"product_id":"amx-nx-2200","title":"AMX NX-2200","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NX-2200 \/ NetLinx® NX Integrated Controller is a programmable network appliance specifically designed to control AV and building technology using multiple analog and digital formats. The NX-2200 provides a scalable platform for the future by combining high performance, backward compatibility and extensive network security features. The NX-2200 is ideal for control and automation of medium-sized rooms and multi-room applications, as it includes more ports and security capabilities than the NX-1200.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual NIC – The LAN port is used to connect the master to an external network, and the ICSLAN ports connect to AMX or third-party A\/V equipment isolated from the primary network, providing rock-solid security\u003c\/li\u003e\n\u003cli\u003eIPv6 – Supports Internet Protocol version 6 (IPv6), the communications protocol that provides an identification and location system for computers on networks and routes traffic across the Internet\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1X – Supports IEEE Standard for Port-based Network Access Control with the ability to grant or deny network access to devices wishing to attach to a LAN based on credentials tied to the device rather than to a user\u003c\/li\u003e\n\u003cli\u003eX.509 Certificate Services – NX supports customer-provided certificates for access to protected networks\u003c\/li\u003e\n\u003cli\u003eFull LDAP Integration – Supports multiple user-defined login groups for accessing the master, as well as provides an AMX programmer the capability to require network login to access certain areas of the touch panel\u003c\/li\u003e\n\u003cli\u003eHigh Performance Architecture, Flexible Programming Platform (RPM, NetLinx and Java) – Easily scalable to support a wide range of applications for today and tomorrow\u003c\/li\u003e\n\u003cli\u003eFull Line Compatible (Backwards and Cross-Compatibility) – Standardized port numbers and new configuration import\/export tools mean fewer coding changes\u003c\/li\u003e\n\u003cli\u003eTLS \/ SSH Client – Provides NetLinx programmers the ability to manage secure port TLS and SSH communications with a remote device or server\u003c\/li\u003e\n\u003cli\u003eCryptographic Support – In accordance with FIPS 140-2, a U.S. government computer security standard used to accredit cryptographic modules for the protection of sensitive or valuable data\u003c\/li\u003e\n\u003cli\u003eNetwork Syslog – Supports standard device logging to a syslog server\u003c\/li\u003e\n\u003cli\u003eEnhanced Diagnostics On Serial and IR Ports – Provides real time error feedback when Serial and IR ports are disconnected or improperly wired\u003c\/li\u003e\n\u003cli\u003eFile Import \/ Export From USB Drive – Backup and restore configuration and program data and update firmware from a standard USB flash drive\u003c\/li\u003e\n\u003cli\u003eHardware \/ Software Built for 24\/7\/365 Operation – Provides outstanding reliability and improved diagnostics\u003c\/li\u003e\n\u003cli\u003eUltra-Fast 1600 MIPS processor\u003c\/li\u003e\n\u003cli\u003e512 MB Onboard RAM\u003c\/li\u003e\n\u003cli\u003e1 M Non-Volatile Memory\u003c\/li\u003e\n\u003cli\u003e8 GB SDHC FLASH Memory\u003c\/li\u003e\n\u003cli\u003e1 RU\u003c\/li\u003e\n\u003cli\u003e1 AXLink Interface\u003c\/li\u003e\n\u003cli\u003e1 10\/100 LAN Interface\u003c\/li\u003e\n\u003cli\u003e4 Digital I\/O Ports\u003c\/li\u003e\n\u003cli\u003e1 RS232\/422\/485 Port\u003c\/li\u003e\n\u003cli\u003e3 RS232-Only Ports\u003c\/li\u003e\n\u003cli\u003e4 IR\/Serial Output Ports\u003c\/li\u003e\n\u003cli\u003e4 Relay Ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (HWD): 1 4\/5” x 17” x 9 1\/8” (45.15 mm x 431.80 mm x 231.64 mm)\u003c\/li\u003e\n\u003cli\u003eWeight: 6.08 lb. (2.758 Kg)\u003c\/li\u003e\n\u003cli\u003eMemory: Memory Card: 8 GB SD, NVRAM: 1 MB, DDRAM: 512 MB, Note: Supports external USB Solid State Drives\u003c\/li\u003e\n\u003cli\u003ePower Consumption: Active Power Consumption: 4.2 W\u003c\/li\u003e\n\u003cli\u003eAxLink Port: (1) 4-position 3.5mm Screw Terminal, provides data and power to external AxLink control devices\u003c\/li\u003e\n\u003cli\u003eAxLink Indicator: (1) AxLink LED (green) indicates the state of the AxLink port\u003c\/li\u003e\n\u003cli\u003eRS-232\/422\/485 Ports: (1) 10-position 3.5mm Screw Terminal, NetLinx Port 1, XON\/XOFF (transmit on \/ transmit off), CTS\/RTS (clear to send\/ready to send), 300 - 115,200 baud\u003c\/li\u003e\n\u003cli\u003eRS-232 Port: (3) 2-position 3.5mm Screw Terminal, NetLinx Ports 2-4, XON\/XOFF (transmit on \/ transmit off), CTS\/RTS (clear to send\/ready to send), 300 - 115,200 baud\u003c\/li\u003e\n\u003cli\u003eSerial Indicator: (4) sets of LEDs (red\/yellow) indicate when serial Ports 1 - 4 are transmitting and receiving data\u003c\/li\u003e\n\u003cli\u003eIR\/Serial: (4) 2-position 3.5mm Screw Terminal, 4 IR Transmit \/ 1-way Serial ports, NetLinx Ports 11-14, Support high-frequency carriers up to 1.142 MHz, 4 IR\/Serial data signals can be generated simultaneously\u003c\/li\u003e\n\u003cli\u003eIR\/Serial Indicators: (2) LEDs (red) indicate when each of the IR\/Serial ports (11-14) are transmitting control data\u003c\/li\u003e\n\u003cli\u003eI\/O Channels: (4) One 6-position 3.5mm Screw Terminal, 4-channel binary I\/O port for contact closure with each input being capable of voltage sensing, NetLinx Port 22, Channels 1-4\u003c\/li\u003e\n\u003cli\u003eI\/O Indicator: (4) LEDs (yellow) indicate each of the I\/O channels (1-4) are active\u003c\/li\u003e\n\u003cli\u003eRelays: (4) One 8-position 3.5 mm Screw Terminal, (4) single-pole, single-throw relays, NetLinx Port 21, Channels 1-4, Each relay can switch up to 24 VDC or 28 VAC @ 1 A, Each relay is independently controlled\u003c\/li\u003e\n\u003cli\u003eRelay Indicators: (4) LEDs (red) indicate when each of the relay channels (1-4) are active (closed)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AMX","offers":[{"title":"Default Title","offer_id":43886807056427,"sku":"AMX-FG2106-02","price":1395.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/AMX-FG2106-02-1__44952.1697797427.1280.1280.jpg?v=1775672577","url":"https:\/\/www.empirepro.com\/products\/amx-nx-2200","provider":"Empire Pro","version":"1.0","type":"link"}