{"product_id":"ashly-ne4250","title":"Ashly NE4250","description":"\u003cp\u003e\u003cspan\u003eTargeted for the performance installation and constant voltage markets these amplifiers add a new level of power and control from the simplest to most advanced audio system applications. The models include both four and eight channel low impedance 25V 70V and 100V amplifiers and provide 250W of power per channel. Network Enabled (NE) amplifiers offer ease of use full setup control and monitoring using standard 10\/100 Ethernet protocol and Protea NE Software. No special outboard control units are needed. NE Series amplifiers are offered two ways; standard input with euroblock connectors and \"pe\" (Protea Enabled) with euroblock input connectors and world renowned Protea DSP signal processing.\u003c\/span\u003e\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cspan\u003eThe DSP library is extensive and utilizes two SHARC 32-bit\/96kHz processors. Processing blocks include Graphic Parametric Notch and Shelving Equalization High- Low- and All-Pass Filters (HPF\/LPF\/APF) with up to 48dB\/Octave slopes Delay Compressor\/Limiter Gate Ducking Auto-leveler Gain and Signal Generators (sinewave white and pink noise). A full Matrix Mixer with assignable routing allows any input to drive any or all amplifier outputs. Presets can be used to store and retrieve global parameters of an entire amplifier's control surface and DSP section.\u003c\/span\u003e\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cspan\u003eAdditionally each amplifier also provides DC voltage control of the attenuators which makes it a snap to control volume from remote locations preset recall Remote Power Standby and data in and out ports for connecting accessories like the WR-5 to control user selected parameters. There are LED indicators for power standby protect network communications and each channel has a four-step signal meter bridge mono temperature and current indicators. Four-channel Mic-pre AES\/EBU and Cobranet input modules will be available as options.\u003c\/span\u003e\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e Features:\u003cbr\u003e Eight and Four Channel Amplifiers\u003cbr\u003e Ethernet control is standard\u003cbr\u003e Low-Z 25V 70V and 100V Models\u003cbr\u003e Extensive DSP Available\u003cbr\u003e Easy and intuitive user interface\u003cbr\u003e Extensive protection circuitry\u003cbr\u003e Safety\/Compliance: cTUVus\/FCC CE (pending) RoHS\u003cbr\u003e Level attenuators for each channel\u003cbr\u003e Power switch can be disabled by software\u003cbr\u003e 4-Step Signal Level and Clip LEDs\u003cbr\u003e 10\/100 Ethernet port\u003cbr\u003e Euroblock inputs and outputs\u003cbr\u003e Remote level control\u003cbr\u003e Preset recall\u003cbr\u003e Remote power standby\u003cbr\u003e Data in and out ports\u003c\/span\u003e\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cdl\u003e\n\u003cdt\u003eFront Panel\u003c\/dt\u003e\n\u003cdd\u003eControls: Individual input attenuators, AC Power Switch\u003cbr\u003eCooling: Temp dependent speed-controlled fan (Front in, Side out)\u003c\/dd\u003e\n\u003cdt\u003eFront Panel LED Indicators: Unit Status\u003c\/dt\u003e\n\u003cdd\u003ePOWER (Blue): Switch: On, Off\u003cbr\u003eSTANDBY (Yellow): Standby, flashing\u003cbr\u003ePROTECT (Red): On, Off\u003cbr\u003eDISABLE (Yellow): On, Off\u003cbr\u003eCOM (Green): On, for Ethernet data or Device ID\u003c\/dd\u003e\n\u003cdt\u003eFront Panel LED Indicators: Each Channel\u003c\/dt\u003e\n\u003cdd\u003eSIGNAL LEVEL:\u003cbr\u003eRed: Clip\u003cbr\u003eYellow: -6dB\u003cbr\u003eGreen: -18dB, -12dB\u003cbr\u003eBRIDGE (Green): Per Channel Pair\u003cbr\u003eTEMP (Yellow): Per Channel\u003cbr\u003eCURRENT (Green): Per Channel: Proportional to output\u003c\/dd\u003e\n\u003cdt\u003eRear Panel: Controls\u003c\/dt\u003e\n\u003cdd\u003eEthernet 10\/100, Channel bridge switch (Low-Z only), Remote standby, Preset recall (4), Remote Level (8), Remote Data\u003c\/dd\u003e\n\u003cdt\u003eRear Panel: Connectors (each channel)\u003c\/dt\u003e\n\u003cdd\u003eInput: Euroblock\u003cbr\u003eOutput: Euroblock\u003c\/dd\u003e\n\u003cdt\u003eFrequency Response\u003c\/dt\u003e\n\u003cdd\u003e20Hz-20kHz, (unweighted) +\/-1dB\u003c\/dd\u003e\n\u003cdt\u003eInput Impedance\u003c\/dt\u003e\n\u003cdd\u003e20k Ohms, Balanced\u003c\/dd\u003e\n\u003cdt\u003eVoltage Gain\u003c\/dt\u003e\n\u003cdd\u003e26dB (Low-Z), 32dB (70V),\u003c\/dd\u003e\n\u003cdt\u003e35dB (100V)\u003c\/dt\u003e\n\u003cdd\u003e6.2dBu (Low-Z), 4.2dBu (25V), 7.2dBu (70V), 7.2dBu (100V)\u003c\/dd\u003e\n\u003cdt\u003eMaximum Input Level\u003c\/dt\u003e\n\u003cdd\u003e+21dBu\u003c\/dd\u003e\n\u003cdt\u003eSoftware Controlled Internal HPF\u003c\/dt\u003e\n\u003cdd\u003e80Hz (12dB\/oct), 400Hz (6dB oct), OFF (25V, 70V, 100V models)\u003c\/dd\u003e\n\u003cdt\u003eDistortion (8 Ohm load)\u003c\/dt\u003e\n\u003cdd\u003e(SMPTE) \u0026lt;0.5% typical\u003cbr\u003e(THD-N) \u0026lt;0.5% typical (20Hz-20kHz)\u003c\/dd\u003e\n\u003cdt\u003eDamping Factor (8 Ohms, 1kHz)\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt;250\u003c\/dd\u003e\n\u003cdt\u003eOutput Circuitry\u003c\/dt\u003e\n\u003cdd\u003eClass D\u003c\/dd\u003e\n\u003cdt\u003eAmplifier\/Load Protection\u003c\/dt\u003e\n\u003cdd\u003eOutput Over current, Main Supply, Rail Overvoltage, Chassis Temperature, Inrush Limiting, Mains Fuse\u003c\/dd\u003e\n\u003cdt\u003eEnvironmental\u003c\/dt\u003e\n\u003cdd\u003e40 to 120deg. F, (4 to 49deg. C) noncondensing\u003c\/dd\u003e\n\u003cdt\u003eAC Main\u003c\/dt\u003e\n\u003cdd\u003e120V or 240V AC, +\/-10% 50-60Hz\u003c\/dd\u003e\n\u003cdt\u003ePower Cable Connector\u003c\/dt\u003e\n\u003cdd\u003e15A Edison, 3-Prong IEC\u003c\/dd\u003e\n\u003cdt\u003eChannels\u003c\/dt\u003e\n\u003cdd\u003e4\u003c\/dd\u003e\n\u003cdt\u003eContinuous Average Power Output\u003c\/dt\u003e\n\u003cdd\u003e8 Ohms: 150W\u003cbr\u003e4 Ohms: 250W (Per Channel, Low Z models, Stereo Mode, All Channels Driven)\u003c\/dd\u003e\n\u003cdt\u003eLow Z Output\u003c\/dt\u003e\n\u003cdd\u003e8 Ohms: 500W (Bridge Mode, All Channels Driven)\u003c\/dd\u003e\n\u003cdt\u003eDistributed Output Models\u003c\/dt\u003e\n\u003cdd\u003e25V (per channel): 250W\u003cbr\u003e70V (per channel): 250W\u003cbr\u003e100V (per channel): 250W (20Hz-20kHz 1% THD)\u003c\/dd\u003e\n\u003cdt\u003eLine Current Draw\u003c\/dt\u003e\n\u003cdd\u003eStandby Mode: 190mA\u003cbr\u003eIdle (no signal): 540mA\u003cbr\u003eTypical (1\/8 power pink noise): 2.85A\u003cbr\u003eMaximum (1\/3 power pink noise): 6.00A (120VAC Mains (divide in half for 230V))\u003c\/dd\u003e\n\u003cdt\u003eThermal Dissipation\u003c\/dt\u003e\n\u003cdd\u003eStandby mode: 46.7\u003cbr\u003eIdle (no signal): 123\u003cbr\u003eTypical (1\/8 power pink noise): 341\u003cbr\u003eMaximum (1\/3 power pink noise): 378 (BTU\/hr, All Channels Driven)\u003c\/dd\u003e\n\u003cdt\u003eSignal to Noise\u003c\/dt\u003e\n\u003cdd\u003e20-20k, Unweighted: \u0026gt;107dB\u003c\/dd\u003e\n\u003cdt\u003eDimensions (W x H x D)\u003c\/dt\u003e\n\u003cdd\u003e19 x 3.5 x 16.84\" (48.26 x 8.89 x 42.77cm)\u003c\/dd\u003e\n\u003cdt\u003eWeight\u003c\/dt\u003e\n\u003cdd\u003e23lbs (10.43kg)\u003c\/dd\u003e\n\u003c\/dl\u003e\r\n\r\n\u003cp\u003e \u003c\/p\u003e\r\n\r\n\u003cp\u003e \u003c\/p\u003e","brand":"Ashly","offers":[{"title":"Default Title","offer_id":43886894383147,"sku":"ASH-ne4250","price":1443.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/ne-4250-rear_3__82210.1683791964.1280.1280.jpg?v=1775673067","url":"https:\/\/www.empirepro.com\/products\/ashly-ne4250","provider":"Empire Pro","version":"1.0","type":"link"}