{"product_id":"chauvet-chamsys-genetixgn4ip","title":"Chauvet Chamsys GENETIXGN4IP","description":"\u003cp\u003e\u003cstrong\u003eGeNetix GN10R\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGeNetix Node 10R is a multipurpose node that provides a solution for remote data distribution in a wide variety of applications, notably offering support for Timecode, MIDI and 10Scene. The R version of our GN10 series comes fitted with RJ45 Ethernet connectors for the DMX outputs that make it well-suited for permanent installation projects.\u003cbr\u003eGeNetix GN4IP\u003c\/p\u003e\n\u003cp\u003eGeNetix Node 4 IP is a compact IP65-rated 4-port Ethernet-to-DMX Node that comes with multiple rigging options for easily mounting in your rig. Featuring 1 Network Port and 4 DMX Outputs that can be used as either DMX In or Out, Port Status LEDs, and the ability to be powered either via PoE or via Mains power to its PowerCon True1 Mains Input connector. This rugged and versatile device can be configured remotely over network via either its inbuilt Webserver, Art-Net or a ChamSys Console.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 RDM DMX Ports supporting Input and Output\u003c\/li\u003e\n\u003cli\u003eSupports Art-Net \u0026amp; sACN\u003c\/li\u003e\n\u003cli\u003eIP65 Rated\u003c\/li\u003e\n\u003cli\u003eWebserver for remote configuration\u003c\/li\u003e\n\u003cli\u003eCan be Mains or PoE powered\u003c\/li\u003e\n\u003cli\u003eWebserver for remote configuration\u003c\/li\u003e\n\u003cli\u003eCore Mode Unlock of up to 2 MagicQ Instances when connected via Network\u003c\/li\u003e\n\u003cli\u003eM12 Threaded Insert for Clamp Mounting\u003c\/li\u003e\n\u003cli\u003eBuilt in Rail for secondary Safety bond when rigged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eGeNetix Protocols\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGeNetix network nodes support industry standard lighting protocols; Art-Net V1,2,3 and 4, sACN – including priorities on a per universe basis and Remote Device Management (RDM).\u003c\/p\u003e\n\u003cp\u003eDMX timings are fully configurable, with refresh rate, break time, frame time and MAB.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eDMX Fallback\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDMX Fallback enables fixtures on a single universe to be connected in a loop to two ports on the GeNetix node for redundancy. If a single cable is broken anywhere in the DMX loop, all fixtures can still receive DMX.\u003c\/p\u003e\n\u003cp\u003eIndividual ports can be set to Output, Input or Fallback.\u003c\/p\u003e\n\u003cp\u003eDMX Fallback is supported within a GeNetix node and also between multiple GeNetix nodes.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMerging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGeNetix nodes support merging, configurable per port. The merge options are: None, HTP, LTP, Lowest IP address, Highest IP address.\u003c\/p\u003e\n\u003cp\u003eWhen set to HTP, for each of the channels on that universe the node uses the highest level received from all sources sending to that universe.\u003c\/p\u003e\n\u003cp\u003eWhen set to LTP, for each of the channels the node uses the data received from the latest source. The node only changes to data from the other source when the data from that source has changed in value, or when the first source has been timed out. LTP merging is only supported for a maximum of two sources.\u003c\/p\u003e\n\u003cp\u003eWhen set to Highest IP address or Lowest IP address the node merges each universe based on the data from the source with the highest or lowest IP address respectively. For example, a house system can be set as a very low IP address and then merging set to “highest IP” to enable incoming consoles to have priority over the house system.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eScenes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGeNetix nodes support storage of 10 Scenes that can be recorded from the incoming Art-Net or sACN data. Scenes contain DMX data for one or more ports on the node.\u003c\/p\u003e\n\u003cp\u003eScenes can be replayed from either the node front panel, from the MagicQ \/ QuickQ Console, via the webserver or via 10Scene wall plates on the GN5 \u0026amp; GN10 Nodes.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eNode Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GeNetix network nodes can be configured from MagicQ consoles and PC systems and from QuickQ consoles. They can also all be configured from a web server. The nodes with a front panel can also be configured from the front panel.\u003c\/p\u003e\n\u003cp\u003eGeNetix nodes also support a lock PIN to prevent the configuration being modified from the front panel of the GeNetix\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eLost Data Behaviour\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGeNetix Nodes support 3 modes for when the node loses network data (Art-Net or sACN)\u003c\/p\u003e\n\u003cp\u003eHold – Holds the last output DMX values\u003c\/p\u003e\n\u003cp\u003eNone – Stops outputting DMX\u003c\/p\u003e\n\u003cp\u003eZeroes – Outputs DMX 0’s on all channels\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eDMX synchronisation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGeNetix nodes support synchronised DMX output to reduce tearing. Synchronisation is controlled via ChamNet and is available when used with MagicQ consoles.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eHardware Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRDM Direct DMX Ports: 4\u003c\/li\u003e\n\u003cli\u003eNetwork Ports: 1\u003c\/li\u003e\n\u003cli\u003eMains Input: PowerCon True1 Top\u003c\/li\u003e\n\u003cli\u003eCan be PoE Powered: Yes\u003c\/li\u003e\n\u003cli\u003ePort Status LEDs: Yes\u003c\/li\u003e\n\u003cli\u003eM12 Clamp Fixing: Yes\u003c\/li\u003e\n\u003cli\u003eSafety Bond Fixing Rail: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eArt-Net\/sACN: Yes\u003c\/li\u003e\n\u003cli\u003eChamNet Support: Yes\u003c\/li\u003e\n\u003cli\u003eConfigurable DMX Timings: Yes\u003c\/li\u003e\n\u003cli\u003eWeb Server: Yes\u003c\/li\u003e\n\u003cli\u003eDMX Redundancy Support: Yes\u003c\/li\u003e\n\u003cli\u003eUser Scene Store: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNeutrik powerCON TRUE1 Power Cable: 1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNode Weights and Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWidth: 274mm (10.81 inches)\u003c\/li\u003e\n\u003cli\u003eDepth: 76mm (3,0 inches)\u003c\/li\u003e\n\u003cli\u003eHeight: 68mm (2.68 inches)\u003c\/li\u003e\n\u003cli\u003eWeight: 1.40 KG (3.09 lb)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Chauvet","offers":[{"title":"Default Title","offer_id":43887314501675,"sku":"CHV-GENETIXGN4IP","price":776.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/gn4ip-right__00712.1759943660.1280.1280.png?v=1775701300","url":"https:\/\/www.empirepro.com\/products\/chauvet-chamsys-genetixgn4ip","provider":"Empire Pro","version":"1.0","type":"link"}