{"product_id":"etc-ermct8-g2-f","title":"ETC ERMCT8-G2-F","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoost Your Circuit Quantity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Unison Echo™ Room Controller provides a complete power solution for small- and medium-sized rooms - all from a single product. Echo Room Controllers feature a multi-space control structure that allow each output of the Room Controller to be assigned to a unique space, or multiple zones to one space. Its feed-thru power input allows a single power input to feed all relays, or a discrete power input for each relay based on your system capacity. Relay and 0-10V control remain individually controlled no matter how the panel is fed.\u003c\/p\u003e\n\u003cp\u003eThe Room Controller also has flexibility to control zones in multiple spaces to maximize efficiency and reduces hardware needs for small systems.\u003c\/p\u003e\n\u003cp\u003eRoom Controllers provide additional interfaces for A\/V integration, Demand Response input from a utility company, and UL924 emergency bypass built into each controller, making it ideal for classrooms, offices, churches and all general area-lighting needs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety First\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEmergency lighting is easy to support with Echo Room Controllers. A UL 924 Sense Feed input for triggering control bypass adds significant emergency lighting control functionality at no additional cost. The integrated normal power sensing eliminates the need for an external Emergency Bypass Detection Kit (EBDK) or other device to generate a contact closure to trigger an Emergency State; but a contact input is also supported when needed.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDemand Response\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnergy codes and energy companies alike have growing requirements to reduce your power consumption during high-energy usage. The Room Controller meets these energy requirements by accepting a contact input from the power company to impose a configured maximum output per zone. This Demand Response state is shared across the EchoConnect control bus, allowing Zone Controllers to participate in the energy reduction effort.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAudio\/Visual Integration \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Room Controller accepts a contact closure from an A\/V system, which allows the lighting to automatically change to a user configured preset to meet the presentation needs of your space. A single action is all it takes to convert your space into presentation mode.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupport System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Room Controller lives on the EchoConnect network to support all Echo power and control products. It comes with built-in EchoConnect bus power, supporting six external stations and five external power-control products. With a wide range of button stations, fader stations, Responsive Controls and Interfaces, the Room Controller gives you the proper controls for almost any installation.  \u003c\/p\u003e\n\u003cp\u003eBoth four- and eight-zone models are available with or without TimeClock support for real and astronomical events.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT FEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePreset control: Looks activated from EchoConnect stations, sensors and TimeClock events\u003c\/li\u003e\n\u003cli\u003eZone control: Circuits grouped to a single control fader; models exist for four or eight zones\u003c\/li\u003e\n\u003cli\u003eManual control: A switch on each relay allows it to be controlled locally without the need for power\u003c\/li\u003e\n\u003cli\u003eSupport for mixed use of 120V, 277V, normal, emergency, and plug-load control in a single controller\u003c\/li\u003e\n\u003cli\u003eUL924 Emergency: Forces on critical lighting while optionally turning off non-critical circuits\u003c\/li\u003e\n\u003cli\u003e0-10V line voltage isolation for each control output. This isolation protects equipment from mains voltage leaks so that equipment can be prepared for any 0-10V driver in the field.\u003c\/li\u003e\n\u003cli\u003eDemand Response: Contact closure sets maximum output to reduce power usage while active\u003c\/li\u003e\n\u003cli\u003eA\/V contact input: Integration with third-party A\/V systems\u003c\/li\u003e\n\u003cli\u003eTimeClock: Events triggered by integral TimeClock for sunrise\/sunset, time of day, and calendar\u003c\/li\u003e\n\u003cli\u003eStation power supply: Integral power supply for up to six stations and power products\u003c\/li\u003e\n\u003cli\u003eHot power: A terminal is available for one hot (uncontrolled) output per zone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eArena and Stadium suites\u003c\/li\u003e\n\u003cli\u003eHouses of worship\u003c\/li\u003e\n\u003cli\u003eEducation\u003c\/li\u003e\n\u003cli\u003eHospitality\u003c\/li\u003e\n\u003cli\u003eHealthcare facilities\u003c\/li\u003e\n\u003cli\u003eOffice buildings\u003c\/li\u003e\n\u003cli\u003eConference rooms\u003c\/li\u003e\n\u003cli\u003eMeeting rooms\u003c\/li\u003e\n\u003cli\u003eRetail\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ETC","offers":[{"title":"Default Title","offer_id":43889200005163,"sku":"ETC-7187A1154","price":949.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/ETC-7187A1143-1__65832.1729482636.1280.1280.jpg?v=1775701057","url":"https:\/\/www.empirepro.com\/products\/etc-ermct8-g2-f","provider":"Empire Pro","version":"1.0","type":"link"}