{"product_id":"etc-erp-12r1-12b1-ml3p","title":"ETC ERP-12R1-12B1-ML3P","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Unison Echo Relay Panel is a control-oriented power center built with today and tomorrow’s lighting loads in mind. It supports up to 24 relays or dimmers with integral branch breakers, power-usage reporting and sophisticated control inputs. With built-in station and sensor support via contact input, DMX and Ethernet connectivity, and optional 0–10 V dimming or DALI output, Echo Relay Panels easily integrate into a broad range of systems and applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTheaters\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003cli\u003eHouses of worship\u003c\/li\u003e\n\u003cli\u003eConference centers\u003c\/li\u003e\n\u003cli\u003eRetail shops and restaurants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Feed Relay panel with feed options for:\n\u003cul\u003e\n\u003cli\u003eThree-phase 120\/208 V four-wire plus ground\u003c\/li\u003e\n\u003cli\u003eSingle-phase 120\/240 V three-wire plus ground\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e24-position relay panel with support for 1-, 2-, or 3-pole relays and support for 300 W phase-adaptive or forward-phase dimmers\u003c\/li\u003e\n\u003cli\u003e30-position breaker subpanel with support for 1-, 2-, or 3-pole breakers, including 1- and 2-pole 120 V GFCI\n\u003cul\u003e\n\u003cli\u003eSingle-pole relay kits fed by 20 A branch breakers are suitable for plug load control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e14 inch width and 4 inch depth allows the cabinet to be flush- or surface-mounted in standard stud-width construction\u003c\/li\u003e\n\u003cli\u003eDMX and Ethernet (sACN) control of preset and sequence playback\u003c\/li\u003e\n\u003cli\u003eLocal user interface provides:\n\u003cul\u003e\n\u003cli\u003ePanel configuration\u003c\/li\u003e\n\u003cli\u003ePreset and sequence programming and playback\u003c\/li\u003e\n\u003cli\u003eIndividual channel control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in Ethernet port\u003c\/li\u003e\n\u003cli\u003eAvailable 0–10 V, contact input, and DALI control cards\u003c\/li\u003e\n\u003cli\u003eUL924 Listed emergency control bypass with load shedding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREGULATORY AND COMPLIANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecULus Listed\u003c\/li\u003e\n\u003cli\u003eUL508 Listed\u003c\/li\u003e\n\u003cli\u003eUL67 Listed\u003c\/li\u003e\n\u003cli\u003eUL924 Listed\u003c\/li\u003e\n\u003cli\u003eComplies with ANSI E1.11 DMX512-A standard\u003c\/li\u003e\n\u003cli\u003eComplies with ANSI E1.31 streaming ACN standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUSER INTERFACE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical display with LED backlight\n\u003cul\u003e\n\u003cli\u003eButton interface with:\u003c\/li\u003e\n\u003cli\u003e0–9 number buttons\u003c\/li\u003e\n\u003cli\u003eUp, down, back and enter navigation buttons\u003c\/li\u003e\n\u003cli\u003eTest shortcut for local activation of preset, sequence and\u003c\/li\u003e\n\u003cli\u003eset level overrides\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB interface for upload of setup and software updates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMECHANICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure constructed of 16-gauge steel finished in black,\u003c\/li\u003e\n\u003cli\u003efine-textured, scratch-resistant powder coat paint\u003c\/li\u003e\n\u003cli\u003eDoor options available for surfaceor recess-mount applications.\n\u003cul\u003e\n\u003cli\u003eFlush-mount door extends 1 inch beyond all panel edges to hide wall cutout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemovable outer panel includes integral locking door to limit access to electronics, breakers and local relay overrides\u003c\/li\u003e\n\u003cli\u003eFull front access with no side clearance required\u003c\/li\u003e\n\u003cli\u003eRemovable covers for access to Class 1 and Class 2 wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain feed power input available to support:\n\u003cul\u003e\n\u003cli\u003e120\/240 V single-phase three-wire plus ground\u003c\/li\u003e\n\u003cli\u003e120\/208 V three-phase four-wire plus ground\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeparate wiring chambers for Class 1 and Class 2 terminations\u003c\/li\u003e\n\u003cli\u003eMax input current: 200 A\u003c\/li\u003e\n\u003cli\u003eMain circuit breaker options: 100 A and 200 A\u003c\/li\u003e\n\u003cli\u003eBranch breaker panel supports three-phase and single-phase subfeed of a second panel up to 100 A\u003c\/li\u003e\n\u003cli\u003eShort-circuit rating: 10,000–42,000 amps symmetrical\u003c\/li\u003e\n\u003cli\u003e10 A, 15 A and 20 A, 1-, 2-, or 3-pole branch circuit breakers; 80% rated\n\u003cul\u003e\n\u003cli\u003e15 A or 20 A, 1or 2-pole 120 V GFCI breakers available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eInrush-pulse tolerance: 8–10.5 times rated current for half-cycle at 60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eENVIRONMENTAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal: 0°C to 40°C (32°F to 104°F) operating temperature\n\u003cul\u003e\n\u003cli\u003eRelays (all) 52.38 BTU\/hr\u003c\/li\u003e\n\u003cli\u003eDimmers (all) 11.78 BTU\/hr\u003c\/li\u003e\n\u003cli\u003eHumidity 5%–95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRELAY RATINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e20 A Ballast (HID)\u003c\/li\u003e\n\u003cli\u003e16 A Electronic Ballast\u003c\/li\u003e\n\u003cli\u003e20 A Tungsten\u003c\/li\u003e\n\u003cli\u003e20 A Motor Load\u003c\/li\u003e\n\u003cli\u003eIsolation: 4000 V RMS\u003c\/li\u003e\n\u003cli\u003eState: Latching; mechanically held\u003c\/li\u003e\n\u003cli\u003eLife:\n\u003cul\u003e\n\u003cli\u003e100,000 cycles at full resistive load\u003c\/li\u003e\n\u003cli\u003e30,000 cycles motor, inductive or tungsten\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCurrent-reporting accuracy: +\/5% of connected load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDIMMER RATINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhase-adaptive (DA), default reverse phase\n\u003cul\u003e\n\u003cli\u003e300 W resistive or electronic load capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eForward-phase (DM)\n\u003cul\u003e\n\u003cli\u003e300 W magnetic or resistive load capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePanel supports up to (24) fully loaded dimmers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCONTROL ELECTRONICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 120–277 V (+\/-15%), 50\/60 Hz, \u0026lt;16 A\u003c\/li\u003e\n\u003cli\u003eMulti-tap transformer terminals accept up to 12 AWG wire\u003c\/li\u003e\n\u003cli\u003eControl wiring terminations:\n\u003cul\u003e\n\u003cli\u003eControl terminals accept maximum of 12 AWG wire\u003c\/li\u003e\n\u003cli\u003eControl wiring exiting the panel are Class 2\u003c\/li\u003e\n\u003cli\u003eAll control terminations utilize removable connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFUNCTIONAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSystem-Wide control\n\u003cul\u003e\n\u003cli\u003eDMX or sACN input\n\u003cul\u003e\n\u003cli\u003ePer-circuit patching\u003c\/li\u003e\n\u003cli\u003ePer-circuit threshold\u003c\/li\u003e\n\u003cli\u003e0-200 prioritization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eConfigurable data loss behavior:\n\u003cul\u003e\n\u003cli\u003ePlay preset; Hold last look; Wait and fade\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUL 924 emergency lighting with load shedding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplication\/Space segmented Control\n\u003cul\u003e\n\u003cli\u003eSpace segmenting: up to 16 spaces per panel\u003c\/li\u003e\n\u003cli\u003ePower Sequencing: one 16-step sequence per space\u003c\/li\u003e\n\u003cli\u003ePresets: up to 64 per space configurable via local UI\u003c\/li\u003e\n\u003cli\u003eZone control: up to 16 zones per space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMonitoring Per Circuit:\n\u003cul\u003e\n\u003cli\u003eBreaker-trip notification\u003c\/li\u003e\n\u003cli\u003eRelay state\u003c\/li\u003e\n\u003cli\u003eCurrent draw, phase voltage, and energy usage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMonitoring Per Space:\n\u003cul\u003e\n\u003cli\u003eActive sequences, presets, and clock events\u003c\/li\u003e\n\u003cli\u003eZone levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e0-10 Dimming Option\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 outputs of 0–10 V sink dimming control rated for 100 mA per output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Input Option\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 dry contact inputs which can be used to:\n\u003cul\u003e\n\u003cli\u003eTrigger presets and sequences, which will play at the priority configured for architectural sources, or;\u003c\/li\u003e\n\u003cli\u003eDirectly control one or more outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDALI Control Option\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 control loops of broadcast DALI control\u003c\/li\u003e\n\u003cli\u003eEach loop supports up to 64 ballasts\u003c\/li\u003e\n\u003cli\u003eExternal DALI power supply required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRideThru Option\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShort-term power backup of control electronics\u003c\/li\u003e\n\u003cli\u003eAutomatically engages when power is lost\u003c\/li\u003e\n\u003cli\u003eRecharges during normal power operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTamper-proof Hardware Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpecial screw heads prevent access to panel interior\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ETC","offers":[{"title":"Default Title","offer_id":43889181327403,"sku":"ETC-7123A1027","price":3656.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/Screenshot_2024-11-22_at_23-46-58_Echo_Relay_Panel_Mains_Feed_Datasheet_revAB.pdf__76123.1732348106.1280.1280.png?v=1775701174","url":"https:\/\/www.empirepro.com\/products\/etc-erp-12r1-12b1-ml3p","provider":"Empire Pro","version":"1.0","type":"link"}