{"product_id":"etc-erp-ft-dali","title":"ETC ERP-FT-DALI","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Unison Drd DalI option provides control output for up to 24 loops of DalI-compatible fluorescent ballasts. the DalI option provides DalI control in a broadcast mode, maintaining dimming performance and requiring no additional configuration during the dimming enclosure set-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHouses of Worship\u003c\/li\u003e\n\u003cli\u003eHotels\u003c\/li\u003e\n\u003cli\u003eConvention Centers\u003c\/li\u003e\n\u003cli\u003emeeting rooms\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003cli\u003emuseums\u003c\/li\u003e\n\u003cli\u003ethemed entertainment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in Unison Drd enclosures\u003c\/li\u003e\n\u003cli\u003eCompatible with Smartlink and Paradigm architectural\u003c\/li\u003e\n\u003cli\u003eControl Processors\u003c\/li\u003e\n\u003cli\u003eSupport for DalI control of fluorescent ballasts in a\u003c\/li\u003e\n\u003cli\u003ebroadcast mode\u003c\/li\u003e\n\u003cli\u003eUp to 64 ballasts may be connected to each loop\u003c\/li\u003e\n\u003cli\u003eUp to 24 loops of DalI control functionally coupled to the\u003c\/li\u003e\n\u003cli\u003edimmer outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGENERAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUl and cUl lISteD\u003c\/li\u003e\n\u003cli\u003eCe marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFUNCTIONAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides broadcast DalI level commands for individual loop control\u003c\/li\u003e\n\u003cli\u003enumber of available outputs dependant on rack enclosure\n\u003cul\u003e\n\u003cli\u003eSupport for up to 24 individual outputs when used in a\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDrd12 rack enclosure\n\u003cul\u003e\n\u003cli\u003eSupport for up to 12 individual outputs when used in a Drd6 rack enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eoutputs functionally coupled one-to-one with the power outputs\u003c\/li\u003e\n\u003cli\u003eCommunication over DalI in broadcast mode controlling all ballasts on a connected loop simultaneously\u003c\/li\u003e\n\u003cli\u003eexternal DalI power supply required for each DalI loop (Provided by others)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMECHANICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to mount inside of Unison Drd dimming enclosures\u003c\/li\u003e\n\u003cli\u003eWiring connections made using removable screw terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eall outputs connections are optically isolated and polarity insensitive\u003c\/li\u003e\n\u003cli\u003eSupports up to 64 DalI ballasts plus one DalI power supply per loop\u003c\/li\u003e\n\u003cli\u003eClass 1 or Class 2 DalI wiring supported\u003c\/li\u003e\n\u003cli\u003eterminals provided for all wiring connections\u003c\/li\u003e\n\u003cli\u003eSupports 12-18 aWG DalI loop wiring\u003c\/li\u003e\n\u003cli\u003emaximum wire length dependant on wire size limitation\u003c\/li\u003e\n\u003cli\u003edetermined in DalI protocol\n\u003cul\u003e\n\u003cli\u003e18 aWG - 570 ft\u003c\/li\u003e\n\u003cli\u003e16 aWG - 900 ft\u003c\/li\u003e\n\u003cli\u003e14 aWG - 1430 ft\u003c\/li\u003e\n\u003cli\u003e12 aWG - 2280 ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHERMAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eambient room temperature: 0-40°C \/ 32-104°f\u003c\/li\u003e\n\u003cli\u003eambient humidity: 30-90% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ETC","offers":[{"title":"Default Title","offer_id":43889186537515,"sku":"ETC-7123K1103","price":409.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/Screenshot_2024-09-23_at_23-07-00_DALI_Option.indd_-_7183L1018_Uni_DRd_DALI_Option_Spec_Sht_vB.pdf__75986.1727158531.1280.1280.png?v=1775677265","url":"https:\/\/www.empirepro.com\/products\/etc-erp-ft-dali","provider":"Empire Pro","version":"1.0","type":"link"}