{"product_id":"etc-erp48-ft482p","title":"ETC ERP48-FT482P","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Echo Relay Panel Feedthrough is a control-oriented switching and power control built with today and tomorrow’s lighting loads in mind. Freely mix normal and emergency 120–347 V single-pole loads and either 120\/208 V or 277\/480 V double-pole loads in the same enclosure. With built-in station and sensor support via contact input, DMX and Ethernet connectivity, and optional 0–10 V dimming or DALI output, Echo Relay Panels easily integrate into a broad range of systems and applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHouses of worship\u003c\/li\u003e\n\u003cli\u003eBallrooms and convention centers\u003c\/li\u003e\n\u003cli\u003eMulti-purpose rooms\u003c\/li\u003e\n\u003cli\u003eArenas and stadiums\u003c\/li\u003e\n\u003cli\u003eEntertainment facilities with DMX control\u003c\/li\u003e\n\u003cli\u003eRetrofits for lighting systems with existing breaker panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e120–347 V single-pole and 120\/208 V or 277\/480 V double-pole switching\u003c\/li\u003e\n\u003cli\u003eUp to 48 relays per panel\u003c\/li\u003e\n\u003cli\u003eSwitches all relays at once or with configurable delay\u003c\/li\u003e\n\u003cli\u003eMechanically latching relays fully rated for 20 A\n\u003cul\u003e\n\u003cli\u003eSingle-pole relay kits fed by 120 V with 20 A branch breakers are suitable for plug load control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual ON\/OFF override with position indication\u003c\/li\u003e\n\u003cli\u003eRelays support field installation and replacement\u003c\/li\u003e\n\u003cli\u003eDMX and Ethernet (sACN) control of preset and sequence playback\u003c\/li\u003e\n\u003cli\u003eLocal user interface provides:\n\u003cul\u003e\n\u003cli\u003ePanel configuration\u003c\/li\u003e\n\u003cli\u003ePreset and sequence programming and playback\u003c\/li\u003e\n\u003cli\u003eIndividual channel control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in Ethernet port\u003c\/li\u003e\n\u003cli\u003eAvailable 0–10 V, contact input, and DALI control cards\u003c\/li\u003e\n\u003cli\u003eUL924 Listed emergency control bypass with load shedding\n\u003cul\u003e\n\u003cli\u003eVoltage barrier for normal\/emergency mixed use panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREGULATORY AND COMPLIANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecULus Listed\u003c\/li\u003e\n\u003cli\u003eUL508 Listed\u003c\/li\u003e\n\u003cli\u003eUL924 Listed\u003c\/li\u003e\n\u003cli\u003eComplies with ANSI E1.11 DMX512-A standard\u003c\/li\u003e\n\u003cli\u003eComplies with ANSI E1.31 streaming ACN standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUSER INTERFACE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical display with LED backlight\u003c\/li\u003e\n\u003cli\u003eButton interface with:\n\u003cul\u003e\n\u003cli\u003e0–9 number buttons\u003c\/li\u003e\n\u003cli\u003eUp, down, back and enter navigation buttons\u003c\/li\u003e\n\u003cli\u003eTest shortcut for local activation of preset, sequence and set level overrides\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB interface for upload of setup and software updates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMECHANICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePanel consists of enclosure, covers with locking doors, and internal subpanels\u003c\/li\u003e\n\u003cli\u003eEnclosure constructed of 16-gauge steel finished in black, fine-textured, scratch-resistant powder coat paint\u003c\/li\u003e\n\u003cli\u003eRemovable conduit panels on top, bottom and sides\u003c\/li\u003e\n\u003cli\u003eFull front access with no side clearance required\u003c\/li\u003e\n\u003cli\u003eRemovable covers for access to Class 1 and Class 2 wiring\u003c\/li\u003e\n\u003cli\u003eLocking doors allow controlled access to manual override switch of each relay and Class 2 wiring only\u003c\/li\u003e\n\u003cli\u003eAll low-voltage wiring is physically separated from AC by a mechanical barrier\u003c\/li\u003e\n\u003cli\u003eRemovable subpanels containing the electronics and relays can ship separately – contact ETC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiscrete feed per circuit supports mixed voltage in a single panel\u003c\/li\u003e\n\u003cli\u003eSingle panel for up to 48 relays, populated in any combination of single- or double-pole\u003c\/li\u003e\n\u003cli\u003eSeparate wiring chambers for Class 1 and Class 2 terminations\u003c\/li\u003e\n\u003cli\u003eOptional voltage barriers install without tools between relays for separation of normal and emergency circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRELAY RATINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e20 A 347 V General Purpose\u003c\/li\u003e\n\u003cli\u003e20 A 347 V Ballast (HID)\u003c\/li\u003e\n\u003cli\u003e20 A Tungsten\u003c\/li\u003e\n\u003cli\u003eMotor Loads:\n\u003cul\u003e\n\u003cli\u003e5 HP @ 120 V\u003c\/li\u003e\n\u003cli\u003e5 HP @ 240\/277 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSCCR: 18,000 A @ 277 V (1P); 5,000 A @ 277 V (2P \u0026amp; 480)\u003c\/li\u003e\n\u003cli\u003eInrush: 2000 A (1P only)\u003c\/li\u003e\n\u003cli\u003eIsolation: 2,500 V RMS\u003c\/li\u003e\n\u003cli\u003eState: Latching\u003c\/li\u003e\n\u003cli\u003eRelays are mechanically held\u003c\/li\u003e\n\u003cli\u003eLife: 60,000 operations at full load\u003c\/li\u003e\n\u003cli\u003eTerminal: Accepts 14–10 AWG copper wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eENVIRONMENTAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal: 0°C to 40°C (32°F to 104°F) operating temperature\n\u003cul\u003e\n\u003cli\u003e20 A relay - 60 BTU\/hr (estimated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHumidity 10%–90%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCONTROL ELECTRONICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 120 or 277 V (+\/-15%), 50\/60 Hz, ≤ 16 A\u003c\/li\u003e\n\u003cli\u003eMulti-tap transformer terminals accept up to 12 AWG wire\u003c\/li\u003e\n\u003cli\u003eControl wiring terminations:\n\u003cul\u003e\n\u003cli\u003eControl terminals accept maximum of 12 AWG wire\u003c\/li\u003e\n\u003cli\u003eControl wiring exiting the panel are Class 2\u003c\/li\u003e\n\u003cli\u003eAll control terminations utilize removable connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFUNCTIONAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRelay modes: Normal (priority\/HTP), latch-lock or last-action\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem-Wide control\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDMX or sACN input\u003c\/li\u003e\n\u003cli\u003ePer-circuit patching\u003c\/li\u003e\n\u003cli\u003ePer-circuit threshold\u003c\/li\u003e\n\u003cli\u003e0–200 prioritization\u003c\/li\u003e\n\u003cli\u003eConfigurable data loss behavior:\u003c\/li\u003e\n\u003cli\u003ePlay preset; Hold last look; Wait and fade\u003c\/li\u003e\n\u003cli\u003eUL 924 emergency lighting with load shedding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication\/Space segmented Control\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpace segmenting: up to 16 spaces per panel\u003c\/li\u003e\n\u003cli\u003ePower Sequencing: one 16-step sequence per space\u003c\/li\u003e\n\u003cli\u003ePresets: up to 64 per space configurable via local UI\u003c\/li\u003e\n\u003cli\u003eZone control: up to 16 zones per space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Per Circuit:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eBreaker-trip notification\u003c\/li\u003e\n\u003cli\u003eRelay state\u003c\/li\u003e\n\u003cli\u003eCurrent draw, phase voltage, and energy usage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Per Space:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eActive sequences, presets, and clock events\u003c\/li\u003e\n\u003cli\u003eZone levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e0–10 V Dimming Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24 outputs of 0–10 V sink dimming control rated for 100 mA per output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Input Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24 dry contact inputs which can be used to:\n\u003cul\u003e\n\u003cli\u003eTrigger presets and sequences, which will play at the priority configured for architectural sources, or;\u003c\/li\u003e\n\u003cli\u003eDirectly control one or more outputs. The priority of these outputs is configurable. If nothing is configured, the last action takes precedence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDALI Control Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24 control loops of broadcast DALI control\u003c\/li\u003e\n\u003cli\u003eEach loop supports up to 64 ballasts\u003c\/li\u003e\n\u003cli\u003eExternal DALI power supply required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRideThru Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eShort-term power backup of control electronics\u003c\/li\u003e\n\u003cli\u003eAutomatically engages when power is lost\u003c\/li\u003e\n\u003cli\u003eRecharges during normal power operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTamper-proof Hardware Kit\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecial screw heads prevent access to panel interior\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ETC","offers":[{"title":"Default Title","offer_id":43889181982763,"sku":"ETC-7123A1125","price":11583.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/ERP24__36720.1727374984.1280.1280.jpg?v=1775691794","url":"https:\/\/www.empirepro.com\/products\/etc-erp48-ft482p","provider":"Empire Pro","version":"1.0","type":"link"}