{"product_id":"etc-iq-lvd","title":"ETC IQ-LVD","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eETC’s Sensor IQ Intelligent Breaker System provides mains-fed power distribution for up to 48 branch circuits in the industry’s most compact footprint. Sensor IQ breakers combine high-inrush rated overcurrent protection, switched power control, and power usage\/breaker status reporting in a single device. With built-in station and sensor support via contact input, DMX and Ethernet connectivity, and optional 0–10 V dimming or DALI output, Sensor IQ panels easily integrate into a broad range of systems and applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTheaters\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003cli\u003eHouses of worship\u003c\/li\u003e\n\u003cli\u003eConference centers\u003c\/li\u003e\n\u003cli\u003eStudios\u003c\/li\u003e\n\u003cli\u003eArenas and stadiums\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMains Feed: Three-phase 120\/208 V four-wire plus ground or single (bi) phase 120\/240 V three-wire plus ground\u003c\/li\u003e\n\u003cli\u003e12-, 24- or 48-position breaker subpanel\u003c\/li\u003e\n\u003cli\u003eBreakers\n\u003cul\u003e\n\u003cli\u003eHydraulic magnetic breaker with high inrush trip curve\u003c\/li\u003e\n\u003cli\u003e22 kA SCCR (up to 65 kA series rated with main breaker)\u003c\/li\u003e\n\u003cli\u003eFreely mix one-, two- and three-pole breakers up to 30 A\u003c\/li\u003e\n\u003cli\u003eIntegrated air-gap relay switching\u003c\/li\u003e\n\u003cli\u003eIntegrated on\/off\/tripped and connected load feedback\u003c\/li\u003e\n\u003cli\u003eNo power required for handle operation at the breaker\u003c\/li\u003e\n\u003cli\u003e20 A single-pole intellingent breakers are suitable for plug load control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDMX and Ethernet (sACN) control of preset and sequence playback\u003c\/li\u003e\n\u003cli\u003eLocal user interface provides:\n\u003cul\u003e\n\u003cli\u003ePanel configuration\u003c\/li\u003e\n\u003cli\u003ePreset and sequence programming and playback\u003c\/li\u003e\n\u003cli\u003eIndividual channel control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in Ethernet port\u003c\/li\u003e\n\u003cli\u003eAvailable 0–10 V, contact input, and DALI control cards\u003c\/li\u003e\n\u003cli\u003eUL924 Listed emergency control bypass with load shedding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREGULATORY AND COMPLIANCE\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBreakers Listed to UL 489\u003c\/li\u003e\n\u003cli\u003eEnclosures listed to UL 67, UL 508, UL 924\u003c\/li\u003e\n\u003cli\u003eComplies with ANSI DMX512-A standard\u003c\/li\u003e\n\u003cli\u003eComplies with ANSI E1.31 streaming ACN standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUSER INTERFACE\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical display\u003c\/li\u003e\n\u003cli\u003eButton interface\n\u003cul\u003e\n\u003cli\u003e0–9 number entry\u003c\/li\u003e\n\u003cli\u003eUp, down and back-arrow navigation with enter\u003c\/li\u003e\n\u003cli\u003eTest shortcut for local activation of preset, sequence and\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eset level overrides\u003c\/li\u003e\n\u003cli\u003eUSB interface for uploads of setup and software updates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBREAKER \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraulic magnetic breaker maintains trip curve through entire thermal range, reducing nuisance tripping Bus connection type: Stab on\u003c\/li\u003e\n\u003cli\u003eOne, two or three poles\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli\u003e15, 20 or 30 A\u003c\/li\u003e\n\u003cli\u003e50\/60 Hz frequency\u003c\/li\u003e\n\u003cli\u003eInrush-pulse tolerance: 25 times rated current for half-cycle\u003c\/li\u003e\n\u003cli\u003eIntegrated hall-effect sensors detect contact positions\u003c\/li\u003e\n\u003cli\u003eIntegrated solenoid for remote operation\u003c\/li\u003e\n\u003cli\u003eTrips on overload even if handle is forcibly held in the “on” position\u003c\/li\u003e\n\u003cli\u003eLoad lugs accept 14-6 AWG load wiring\u003c\/li\u003e\n\u003cli\u003eMulti-conductor rated output terminal\u003c\/li\u003e\n\u003cli\u003eIntegral mechanically held air gap relay\u003c\/li\u003e\n\u003cli\u003eIntegral current sensing\u003c\/li\u003e\n\u003cli\u003eIntegral position and trip sensing\u003c\/li\u003e\n\u003cli\u003eSupports manual control of relay state using breaker handle without power\u003c\/li\u003e\n\u003cli\u003eControl and status provided by contact pads directly at bottom of the breaker case. No external wires or connections required for control or feedback\u003c\/li\u003e\n\u003cli\u003eRemote Feedback for breaker state, breaker type, current draw and phase voltage\u003c\/li\u003e\n\u003cli\u003eVisible state indication:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMECHANICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure constructed of 16-gauge steel finished in black, fine-textured, scratch-resistant powder coat paint\u003c\/li\u003e\n\u003cli\u003eRemovable outer panel includes integral locking door to limit access to electronics, breakers and local relay overrides\u003c\/li\u003e\n\u003cli\u003eFull front access with no side clearance required\u003c\/li\u003e\n\u003cli\u003eRemovable covers for access to Class 1 and Class 2 wiring\u003c\/li\u003e\n\u003cli\u003eComplies with California building code - seismic zone four\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMains feed power input to support 120\/208 V three-phase four-wire or 120\/240 V bi-phase three-wire plus ground•\u003c\/li\u003e\n\u003cli\u003eMax current input: 100 A at 12 circuits, 200 A at 24 circuits, and 400 A at 48 circuits\u003c\/li\u003e\n\u003cli\u003eQuiescent draw: \u0026lt;10 W with relays at steady state\u003c\/li\u003e\n\u003cli\u003eOptional isolation between chassis and equipment grounding\u003c\/li\u003e\n\u003cli\u003eShort-circuit current rating: 22,000 A or 65,000 A symmetrical (see chart a right)\u003c\/li\u003e\n\u003cli\u003eOverloads occurs at 50 operations of 600% of rated current\u003c\/li\u003e\n\u003cli\u003eIntegrated current transformer\u003c\/li\u003e\n\u003cli\u003eCurrent measurement range of 1–30 A. The maximum crest factor of primary current is 2.5\u003c\/li\u003e\n\u003cli\u003eFeeder entry supported at top or top side\n\u003cul\u003e\n\u003cli\u003eBottom or bottom side entry supported by rotating enclosure during installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLoad wire entry supported on top, sides or bottom\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eENVIRONMENTAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal: 0°C to 40° C (32°F to 104° F) operating temperature\n\u003cul\u003e\n\u003cli\u003e24 A circuit (30 A breaker) - 1.4 W, 4.8 BTU\/hr\u003c\/li\u003e\n\u003cli\u003e16 A circuit (20 A breaker) - 1 W, 3.4 BTU\/hr\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHumidity; 5%–95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eComplies with ESD immunity to IEC standard 1000-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCONTROL ELECTRONICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 120–277 V (+\/-15%), 50\/60 Hz, \u0026lt;16 A\u003c\/li\u003e\n\u003cli\u003eMulti-tap transformer terminals accept up to 12 AWG wire\u003c\/li\u003e\n\u003cli\u003eControl wiring terminations:\n\u003cul\u003e\n\u003cli\u003eControl terminals accept maximum of 12 AWG wire\u003c\/li\u003e\n\u003cli\u003eControl wiring exiting the panel are Class 2\u003c\/li\u003e\n\u003cli\u003eAll control terminations utilize removable connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFUNCTIONAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem-Wide control\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDMX or sACN input\n\u003cul\u003e\n\u003cli\u003ePer-circuit patching\u003c\/li\u003e\n\u003cli\u003ePer-circuit threshold\u003c\/li\u003e\n\u003cli\u003e0–200 prioritization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eConfigurable data loss behavior:\n\u003cul\u003e\n\u003cli\u003ePlay preset; Hold last look; Wait and fade\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUL 924 emergency lighting with load shedding\n\u003cul\u003e\n\u003cli\u003eLoad shedding requires a UPS Control Backup Wiring Kit (7131K1817) and Uninterruptable Power Supply (UPS) by others\u003c\/li\u003e\n\u003cli\u003eUPS to supply 800 W–2400 W AC power to control processor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication\/Space segmented Control\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpace segmenting: up to 16 spaces per panel\u003c\/li\u003e\n\u003cli\u003ePower Sequencing: one 16-step sequence per space\u003c\/li\u003e\n\u003cli\u003e-  Presets: up to 64 per space configurable via local UI\u003c\/li\u003e\n\u003cli\u003e- Zone control: up to 16 zones per space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Per Circuit:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eBreaker-trip notification\u003c\/li\u003e\n\u003cli\u003eRelay state\u003c\/li\u003e\n\u003cli\u003eCurrent draw, phase voltage, and energy usage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Per Space:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eActive sequences, presets, and clock events\u003c\/li\u003e\n\u003cli\u003eZone levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e0-10 Dimming Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24 outputs of 0–10 V sink dimming control rated for 100 mA per output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eContact Input Option\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e24 dry contact inputs which can be used to:\n\u003cul\u003e\n\u003cli\u003etrigger presets and sequences, which will play at the priority configured for architectural sources, or;\u003c\/li\u003e\n\u003cli\u003edirectly control one or more outputs. The priority of these outputs is configurable. If nothing is configured, the last action takes precedence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDALI Control Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24 control loops of broadcast DALI control\u003c\/li\u003e\n\u003cli\u003eEach loop supports up to 64 ballasts\u003c\/li\u003e\n\u003cli\u003eExternal DALI power supply required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRideThru Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eShort-term power backup of control electronics\u003c\/li\u003e\n\u003cli\u003eAutomatically engages when power is lost\u003c\/li\u003e\n\u003cli\u003eRecharges during normal power operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPS Backup Kit for Load Shedding\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows Power Control Processor to be powered via external\u003c\/li\u003e\n\u003cli\u003eUPS (by others)\u003c\/li\u003e\n\u003cli\u003eRequired for load shedding applications\u003c\/li\u003e\n\u003cli\u003eUPS provides power to drive relays off when normal power is lost\u003c\/li\u003e\n\u003cli\u003eUPS for each Sensor IQ panel must by UL 924 Listed and\u003c\/li\u003e\n\u003cli\u003erated for a minimum of 200 W peak load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBranch Circuit Fuse Kit\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAids engineers in selective coordination* of\u003c\/li\u003e\n\u003cli\u003eemergency circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ETC","offers":[{"title":"Default Title","offer_id":43889186668587,"sku":"ETC-7131K1303","price":487.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/Sensor_IQ_120V_Datasheet_revW__31335.1727086506.1280.1280.jpg?v=1775699832","url":"https:\/\/www.empirepro.com\/products\/etc-iq-lvd","provider":"Empire Pro","version":"1.0","type":"link"}