{"product_id":"etc-ufmp8","title":"ETC UFMP8","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Foundry Mini Panels offer up to eight zones of DMX controlled lighting with fully rated 20 A relays and optional 0–10 V control per zone. The Mini Panel features a Demand Response input for energy saving integration and a UL 924 emergency lighting control bypass with power loss sense. The Mini Panel is available in flush-mount or surface-mount options and can be located in an air plenum to be easily tucked out of sight.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eArena and stadium suites\u003c\/li\u003e\n\u003cli\u003eOffice buildings\u003c\/li\u003e\n\u003cli\u003eConference and meeting rooms\u003c\/li\u003e\n\u003cli\u003eHealthcare facilities\u003c\/li\u003e\n\u003cli\u003eHouses of worship\u003c\/li\u003e\n\u003cli\u003eClassrooms\u003c\/li\u003e\n\u003cli\u003eHospitality and restaurants\u003c\/li\u003e\n\u003cli\u003eRetail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitched power control of four or eight circuits with 0–10 V dimming\u003c\/li\u003e\n\u003cli\u003e120 or 277 VAC power input per zone\u003c\/li\u003e\n\u003cli\u003e20 A fully rated relays for use with general purpose, tungsten, fluorescent, LED and plug loads\u003c\/li\u003e\n\u003cli\u003e0–10 V dimming output per zone for direct connection to dimming ballasts and LED drivers\u003c\/li\u003e\n\u003cli\u003eDemand Response load shedding contact input\u003c\/li\u003e\n\u003cli\u003eFlush-mount and surface-mount options\u003c\/li\u003e\n\u003cli\u003eUL924 control bypass via\n\u003cul\u003e\n\u003cli\u003eContact closure input\u003c\/li\u003e\n\u003cli\u003eNormal power loss sense feed terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDMX controlled and RDM configurable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eREGULATORY AND COMPLIANCE\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecULus and UL 924 LISTED\u003c\/li\u003e\n\u003cli\u003eRated for plenum installation\u003c\/li\u003e\n\u003cli\u003eSuitable for plug load control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFUNCTIONAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl for up to eight zones of switching for lighting and plug loads\u003c\/li\u003e\n\u003cli\u003eControl for up to eight zones of 0–10 V dimming for LED drivers and fluorescent ballasts\u003c\/li\u003e\n\u003cli\u003eUL 924 emergency-lighting control via contact closure and power loss sense feed terminal\u003c\/li\u003e\n\u003cli\u003eDemand Response input provided by a power company can enforce a maximum level per circuit while active\u003c\/li\u003e\n\u003cli\u003eSupports USITT DMX512-A (ANSI E1.11)\u003c\/li\u003e\n\u003cli\u003eSupports RDM (ANSI E1.20)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMECHANICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConstructed of 16-gauge cold-rolled steel, finished in fine-textured, black powder coat\u003c\/li\u003e\n\u003cli\u003eWall-mount installation; rated for installation in plenum air space\u003c\/li\u003e\n\u003cli\u003eClass 1 voltage barrier prevents access to line-voltage wiring with front panel removed\u003c\/li\u003e\n\u003cli\u003eAvailable in flush-mount and surface-mount options\u003c\/li\u003e\n\u003cli\u003eOptional voltage divider allows for separation of normal and emergency circuits in a single controller where allowed by local codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100–277 VAC, 50\/60 Hz power input per circuit with support for pass thru to multiple circuits\u003c\/li\u003e\n\u003cli\u003e100–277 VAC single phase sense feed input\u003c\/li\u003e\n\u003cli\u003eSupports 120 VAC and 277 VAC circuits within the same panel\u003c\/li\u003e\n\u003cli\u003e20 A, fully-rated bi-state latching relay per output\u003c\/li\u003e\n\u003cli\u003e0–10 VDC control rated for up to 100 mA sink per output\n\u003cul\u003e\n\u003cli\u003e0–10 V outputs are fully isolated from ground to 2500 V RMS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eControl circuit power draw: 0.5A\u003c\/li\u003e\n\u003cli\u003eRising clamp screw terminal wiring connections for:\n\u003cul\u003e\n\u003cli\u003eLine-voltage relay power input, output and pass-through with support for 2.5-10 mm2 (14-8 AWG) wire\u003c\/li\u003e\n\u003cli\u003eController power input and UL 924 Sense circuit with support for 0.5-4 mm2 (20-12 AWG) wire\u003c\/li\u003e\n\u003cli\u003eLow-voltage 0–10 V dimming output per zone with support for 0.5-1.5 mm2 (22-16 AWG) wire\u003c\/li\u003e\n\u003cli\u003eSeparate normal power sense feed input for UL 924 emergency lighting bypass\u003c\/li\u003e\n\u003cli\u003eUL 924 emergency lighting control contact closure input with support for 0.5-1.5 mm2 (22-16 AWG) wire\u003c\/li\u003e\n\u003cli\u003eDemand Response contact input with support for 0.5-1.5 mm 2 (22-16 AWG) wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDemand Response input supports Normally Open (NO) operation\u003c\/li\u003e\n\u003cli\u003eUL 924 contact closure input supports normally open (NO) or normally closed (NC) operation\u003c\/li\u003e\n\u003cli\u003eOnboard status indicators for controller power, DMX signal, Demand Response input, and UL 924 emergency lighting control\u003c\/li\u003e\n\u003cli\u003eSlide switch configuration for:\n\u003cul\u003e\n\u003cli\u003eUL 924 operation (NO\/NC)\u003c\/li\u003e\n\u003cli\u003eUL 924 inclusion per circuit (on\/off)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRELAY RATINGS\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e20 A Magnetic Ballast (HID)\u003c\/li\u003e\n\u003cli\u003e16 A Electronic Ballast\u003c\/li\u003e\n\u003cli\u003e20 A Tungsten\u003c\/li\u003e\n\u003cli\u003e20 A (120 A Locked-rotor) Motor @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e14 A (84 A Locked-rotor) Motor @ 277 VAC\u003c\/li\u003e\n\u003cli\u003eRelays are mechanically held\u003c\/li\u003e\n\u003cli\u003eLifespan:\n\u003cul\u003e\n\u003cli\u003e100,000 cycles at full resistive load\u003c\/li\u003e\n\u003cli\u003e30,000 cycles motor, inductive or tungsten\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDMX INPUT PORT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptically-isolated input from the Mini Panel electronics\u003c\/li\u003e\n\u003cli\u003eWithstands fault voltages of up to 250VAC\u003c\/li\u003e\n\u003cli\u003eIntegrated DMX\/RDM termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCONFIGURATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote configuration available via RDM devices such as:\n\u003cul\u003e\n\u003cli\u003eETC control console with RDM functionality\u003c\/li\u003e\n\u003cli\u003eETC DMX\/RDM gateway networked to a device running ETC Net3 Concert software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual configuration of the starting DMX address, UL 924 bypass, and Demand Response on the controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHERMAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient room temperature: 0°–50° C (32°–122° F)\u003c\/li\u003e\n\u003cli\u003eAmbient humidity: 5–95% (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ETC","offers":[{"title":"Default Title","offer_id":43889189978155,"sku":"ETC-7179A1028","price":765.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/307239__70840.1727689822.1280.1280.jpg?v=1775691852","url":"https:\/\/www.empirepro.com\/products\/etc-ufmp8","provider":"Empire Pro","version":"1.0","type":"link"}