{"product_id":"focusrite-ams-rednet-d64r","title":"Focusrite AMS-REDNET-D64R","description":"\u003ch3\u003eoverview\u003c\/h3\u003e\r\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\r\n\u003ch4\u003e\u003cspan data-sheets-value=\"{\" ams-rednet-d64r data-sheets-userformat=\"{\" sans-serif\u003eFocusrite AMS-REDNET-D64R\u003c\/span\u003e\u003c\/h4\u003e\r\n\u003cp\u003e\u003cspan data-sheets-value=\"{\" ams-rednet-d64r data-sheets-userformat=\"{\" sans-serif\u003e\u003cspan\u003eRedNet D64R provides the link between a Dante Ethernet-based audio system and any MADI \/ AES10 setup. D64R supports up to 64 channels of both coaxial and optical MADI interfaces and is completely bi-directional, allowing the use of any Dante components including RedNet’s high quality interface products with a MADI system – or MADI components with a Dante system. D64R features a sample rate converter (SRC) on each input and output allowing interfacing between MADI and Dante irrespective of the sample rate at which either system is operating. Connect a Dante network to MADI-based digital consoles, computer cards, converters and much more. In addition to both coax and optical MADI interfaces, RedNet D64R provides Word Clock in and out. The D64R features a rugged, roadworthy exterior and high internal build quality, with Ethernet and power supply redundancy. In addition, it offers a compact 1U rack-mount form factor for a full 64 channels of I\/O.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\r\n\u003ch3\u003eFeatures\u003c\/h3\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eConnects a MADI system and a Dante network seamlessly together. Connect Dante to digital mixing consoles, interfaces and cards that use MADI; or extend a MADI system with RedNet’s versatile, superb-quality audio interfaces and connectivity – or any other Dante compatible devices.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eBuilt-in redundancy with dual locking power and etherCON network connectors.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eSupports both coax and optical interfaces – connect simply to any MADI equipment.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eSlave either the Dante system or MADI streams to an external clock\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eSupports up to 64 channels of digital audio I\/O at standard sample rates (44.1\/48kHz) from a MADI system, 32 channels at 96kHz and 16 at 192kHz.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eSample rate conversion (SRC) on each input and output, allowing MADI and Dante systems to operate simultaneously at different sample rates.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eSimple 1U rack-mount module with the classic red aluminium faceplate.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eComprehensive remote control software with powerful graphic user interface\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch3 id=\"page-title\" class=\"title\"\u003eSpecifications\u003c\/h3\u003e\r\n\u003ctable style=\"width: 757px; height: 1509px;\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\" colspan=\"2\"\u003e\n\u003cstrong\u003eSample Rate Convertors\u003c\/strong\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eSample Rate Range\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e41 to 216kHz (MADI)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eGain Error\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e-0.01dB\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eDynamic Range\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e\u0026gt; 139dB (-60 dBFS method)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eTHD + N\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e\u0026lt; -130dB (0.00003%); 0 dBFS input\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eLatency\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e43 to 196 samples (Network and MADI sample rate dependent).\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eMADI Clock Sources\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eRedNet, MADI Input and Word Clock.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eDigital Performance\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eSupported Sample Rates\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e44.1 \/ 48 \/ 88.2 \/ 96 \/ 176.4 \/ 192 kHz (-4% \/ -0.1% \/ +0.1% \/ +4.167%) at 24 bit\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eClock Sources\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eInternal, MADI or from Dante Network Master.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eExternal Word Clock Range\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eNominal sample rate ±7.5%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eRear Panel Connectivity\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl67\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eMADI Coaxial\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eElectrical Standard\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eas per AES10:2008\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eRecommended Cable\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e75Ω Characteristic Impedance\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eConnector\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eBNC 75Ω port\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl67\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eMADI Optical\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eOptical Standard\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eas per AES10:2008 (ISO\/IEC 9314-3, FDDI, ANSI X3.166)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\" rowspan=\"4\"\u003eRecommended Cable\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e(OM1) Multi-Mode, Graded-Index, 62.5µm core, 125µm cladding\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003e(OM2) Multi-Mode, Graded-Index, 50µm core, 125µm cladding\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eOM1 adheres to AES10:2008\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eRedNet 6\/ D64R supports OM2 if 3rd Party Device also supports OM2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eConnector\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eDuplex-SC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl67\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eWord Clock\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eWord Clock Input\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e1 x BNC 75Ω port (switchable termination)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eWord Clock Output\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e1 x BNC 75Ω port\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl67\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003ePSU \u0026amp; Network Connections\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003ePSU\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e2 x IEC Inputs with retaining clips.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eNetwork\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e2 x etherCON NE8FBH-S, also compatible with standard RJ45 connectors (Accomodates rugged etherCON NE8MC*. Does not intermate with Cat 6 cable connector NE8MC6-MO and NKE65* cable)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eFront Panel Indicators\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003ePrimary PSU (A)\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eGreen LED. Illuminates when an AC input is applied and all DC outputs are present.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eSecondary PSU (B)\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eGreen LED. Illuminates when an AC input is applied and all DC outputs are present.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003ePrimary Network\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eGreen LED. Indicates that a network connection is present on primary port when in redundant mode. When in Switched mode, a valid network connection at either Primary or Secondary network port will cause this LED to illuminate.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eSecondary Network\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eGreen LED. Indicates that a network connection is present on secondary port when in redundant mode. Not used in switched mode.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eNetwork Locked\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eGreen LED. When unit is network slave, shows valid network lock. When unit is network master, shows lock to indicated clock source. Flashing indicates external clock is selected but not connected.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eSample Rate\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eOrange LED for each: 44.1 kHz, 48 kHz, x2, x4.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003ePull Up\/Down\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eOrange LED. Indicates unit is set to operate on a Dante pull up\/down domain.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eClock Source\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eOrange LED for each: Internal, MADI Input and Word Clock.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eMADI Input\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eOrange LED for each: Coaxial, Optical and Auto.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eMADI Clock\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eOrange LED for each: SRC, RedNet, MADI Input and Word Clock.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eSignal Indicators\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e2 Green LEDs, 1 input\/1 output indicator. Illuminate @ -126dBFS.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eStatus\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eOrange LED for each: SRC \u0026amp; O\/P Varispeed.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eNetwork Modes\u003c\/strong\u003e\u003c\/div\u003e\r\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eRedundant\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eAllows unit to connect two independent networks.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eSwitched\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eConnects both ports to integrated network switch allowing daisy-chaining of device.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eHeight\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e44.5mm\/ 1.75\"\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eWidth\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e482.6mm\/ 19\"\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr data-populated-cells=\"2\"\u003e\r\n\u003ctd class=\"xl66\"\u003eDepth\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e308mm\/ 12.13\"\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\"\u003e\r\n\u003cdiv\u003eWeight\u003c\/div\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eWeight\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e4.32kg\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\"\u003e\r\n\u003cdiv\u003ePower\u003c\/div\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003ePSU\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003e2 x Internal, 100-240V, 50\/60Hz, consumption 30VA.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl65\" colspan=\"2\"\u003e\r\n\u003cdiv\u003e\u003cstrong\u003eHeat Performance\u003c\/strong\u003e\u003c\/div\u003e\r\n \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"xl66\"\u003eOperating Temperature\u003c\/td\u003e\r\n\u003ctd class=\"xl66\"\u003eOperates at up to an ambient temperature of 50 degrees Celcius\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e","brand":"Focusrite","offers":[{"title":"Default Title","offer_id":43892505673771,"sku":"FOC-AMS-REDNET-D64R","price":3088.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/d64r_rear_lrg-22t__97967.1682441831.1280.1280.jpg?v=1775678409","url":"https:\/\/www.empirepro.com\/products\/focusrite-ams-rednet-d64r","provider":"Empire Pro","version":"1.0","type":"link"}