{"product_id":"kramer-bcls-33","title":"Kramer BCLS-33","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKramer's BCLS−33 is a high−performance CAT 6A F\/UTP cable designed for IT, LAN and Ethernet installations. It is constructed with 23AWG solid bare copper conductors with a cross filler and overall metal foil screen with a drain wire. It is enclosed in an LSZH jacket with sequential markings every meter and packed on a fumigated plywood reel. BCLS−33 cable exceeds CAT 6A specifications to provide additional performance and bandwidth beyond the basic standard.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh–Performance Transmission.\u003c\/li\u003e\n\u003cli\u003eHigh–Quality Safety Properties.\u003c\/li\u003e\n\u003cli\u003eSweep Frequency up to 650MHz.\u003c\/li\u003e\n\u003cli\u003eLength — Available in length of 500m (1640ft).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStructure cabling for horizontal and building backbone cable\u003c\/li\u003e\n\u003cli\u003eIT, LAN and Ethernet installations\u003c\/li\u003e\n\u003cli\u003eIdeal for 10GbE and and legacy speeds applications\u003c\/li\u003e\n\u003cli\u003eIEEE 802.3af (PoE) \/ IEEE 802.3at (PoE+)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONSTRUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductor: 4 pairs of 23AWG solid bare copper\u003c\/li\u003e\n\u003cli\u003eInsulation: Polyolefin (PO)\u003c\/li\u003e\n\u003cli\u003eInsulation: blue \u0026amp; white\/blue stripe, orange \u0026amp; white\/orange stripe, green \u0026amp; white\/green stripe, brown \u0026amp; white\/brown stripe\u003c\/li\u003e\n\u003cli\u003eTwist: Left–hand\u003c\/li\u003e\n\u003cli\u003eAssembly: Left hand direction\u003c\/li\u003e\n\u003cli\u003eRip Shield: Mylar tape\u003c\/li\u003e\n\u003cli\u003eDrain Wire: 24AWG solid tinned copper\u003c\/li\u003e\n\u003cli\u003eShield: Al Mylar tape, 100% coverage and mylar side facing out\u003c\/li\u003e\n\u003cli\u003eJacket: Low smoke zero halogen (LSZH), orange (Pantone 1485C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePolyolefin (PO)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDIAMETERS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket: Diameter: 7.6 ±0.2mm\u003c\/li\u003e\n\u003cli\u003eJacket: thickness: 0.55 ±0.05mm\u003c\/li\u003e\n\u003cli\u003eInsulation: Blue \u0026amp; white\/blue stripe: 1.15 ± 0.02mm\u003c\/li\u003e\n\u003cli\u003eInsulation: Orange \u0026amp; white\/orange stripe: 1.11 ± 0.02mm\u003c\/li\u003e\n\u003cli\u003eInsulation: Green \u0026amp; white\/green stripe: 1.15 ± 0.02mm\u003c\/li\u003e\n\u003cli\u003eInsulation: Brown \u0026amp; white\/brown stripe: 1.11 ± 0.02mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRICAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature \u0026amp; Voltage Rating: 60°C @300V\u003c\/li\u003e\n\u003cli\u003eSpark Test: 2.5kV DC\u003c\/li\u003e\n\u003cli\u003eAC Leakage Current: ≤10mA (1.5kV AC) through overall jacket\u003c\/li\u003e\n\u003cli\u003eConductor DC Resistance: ≤9.38Ω \/100m\u003c\/li\u003e\n\u003cli\u003eResistance Unbalance: ≤5%\u003c\/li\u003e\n\u003cli\u003eDielectric Strength: 1.5kV AC for 2sec\u003c\/li\u003e\n\u003cli\u003eInsulation Resistance: ≥5000MΩ \/m\u003c\/li\u003e\n\u003cli\u003eMutual Capacitance: ≤5.6nF \/100m\u003c\/li\u003e\n\u003cli\u003eCapacitance Unbalance: ≤330pF \/100m pair–to–ground\u003c\/li\u003e\n\u003cli\u003eCharacteristic Impedance: 100±15Ω @1~100MHz\u003c\/li\u003e\n\u003cli\u003eCoupling Attenuation: ≤55dB @30MHz, ≤41dB @500MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUSAGE AND ENVIRONMENTAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCable Cold Bend: –20°C for 4hr\u003c\/li\u003e\n\u003cli\u003eInsulation Tensile Strength: 2400 PSI min. (1.69kg\/m.sq)\u003c\/li\u003e\n\u003cli\u003eNVP: 67%\u003c\/li\u003e\n\u003cli\u003eTemperature Range: Storage \u0026amp; shipping: — 20°C to 60°C\u003c\/li\u003e\n\u003cli\u003eTemperature Range: installation: 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003eTemperature Range: operation: — 20°C to 60°C\u003c\/li\u003e\n\u003cli\u003eMinimum Bending Radius: ≥4 times of overall diameter\u003c\/li\u003e\n\u003cli\u003eMaximum Pulling Tension: ≤110N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREGULATORY PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eANSI\/TIA-568-C.2 (2009): Balanced Twisted–Pair Telecommunications Cabling and Components Standards\u003c\/li\u003e\n\u003cli\u003eISO\/IEC 11801 (Edition 2.2): Information technology — Generic cabling for customer premises\u003c\/li\u003e\n\u003cli\u003eIEC 61156-5 (Edition 2.0): Multicore and symmetrical pair\/quad cables for digital communications — Part 5: Symmetrical pair\/quad cables with transmission characteristics up to 1000 MHz — Horizontal floor wiring — Sectional specification\u003c\/li\u003e\n\u003cli\u003eEN 50288-6-1:2013: Multi–element metallic cables used in analogue and digital communication and control — Part 6–1: Sectional specification for unscreened cables characterized up to 250MHz — Horizontal and building backbone cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEN 50173-12011\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInformation technology. Generic cabling systems. General requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREGULATORY SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions — Part 1–2: Test for vertical flame propagation for a single insulated wire or cable — Procedure for 1kW pre–mixed flame\u003c\/li\u003e\n\u003cli\u003eIEC 61034-1 \/ 61034-2: Measurement of smoke density of cables burning under defined conditions\u003c\/li\u003e\n\u003cli\u003eIEC 60754-2: Test on gases evolved during combustion of materials from cables\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kramer","offers":[{"title":"Default Title","offer_id":43893178531883,"sku":"KRMR-99-46310500","price":328.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/bcls-33___57760.1724827135.1280.1280.jpg?v=1775680348","url":"https:\/\/www.empirepro.com\/products\/kramer-bcls-33","provider":"Empire Pro","version":"1.0","type":"link"}