{"product_id":"powersoft-x8-dsp-eth","title":"Powersoft X8 DSP+ETH","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePowersoft \u003cstrong\u003eX8\u003c\/strong\u003e innovates and evolves the concept of the amplification platform thanks to the integration of a worldwide compatible three-phase power supply and a fully-featured DSP.\u003c\/p\u003e\n\u003cp\u003eThe complete digital audio signal management system based on ARM Cortex A-8 processor and TI C6000 DSP platform heralds new and innovative level of signal processing, providing non-boolean routing and mixing, multi-stage equalization with raised-cosine, IIR and FIR filters, delay up to 2s in input processing and 100ms for time alignment, gain and polarity adjustment, crossover, peak limiters, TruePower™ limiters, and Active DampingControl™.\u003c\/p\u003e\n\u003cp\u003eThe power supply permits worldwide AC acceptance and direct connection to any regional power line configuration: it is now suitable for Single Phase, Bi-Phase, or Three Phase operation from 85 VAC up to 440 VAC without the need for manual selection. True Three Phase load balancing is directly achievable by the unit without any complex load assignment in the power distribution system design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cstrong\u003e​\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for Single-Phase, Two-Phase or Three-Phase operation from 85 VAC up to 440 VAC, with automatic switching and balancing​\u003c\/li\u003e\n\u003cli\u003eThree-phase load balancing directly managed by the unit without the need for complex load assignments in the system design​\u003c\/li\u003e\n\u003cli\u003ePower Factor Correction PFC for low power consumption and compatibility with a wide range of voltages​\u003c\/li\u003e\n\u003cli\u003ePower limiters that eliminate the need for expensive power sequencers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFully protected circuit design with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInnovative failure protection aimed at keeping the system on its SOA by detecting the power delivered to speakers compared to the power drawn from mains​\u003c\/li\u003e\n\u003cli\u003eReal-time measurement and processing of the output signal in order to obtain the power output: all data are collected and compared with data about the available stored energy and the power available from the mains. This makes the system immune from any misalignment such as overvoltage, overcurrent, short circuit, etc.​\u003c\/li\u003e\n\u003cli\u003eProtection against potentially harmful signals: DC, VHF, and clipping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible routing\/mixing provided by the internal 8×8 input\/ output matrix, allows the user to mix and route analog and digital I\/O. ​\u003c\/li\u003e\n\u003cli\u003e8 input channels with physical analog and digital AES3 connectors and optional 16-in\/8-out redundant Dante™ connection provides maximum flexibility.​\u003c\/li\u003e\n\u003cli\u003eImproved reliability thanks to the customizable input backup policy that automatically switches input source in case of a signal failure. ​\u003c\/li\u003e\n\u003cli\u003eComplete user interface integrated into ArmoníaPlus. ​\u003c\/li\u003e\n\u003cli\u003eWiFi remote monitoring through mobile device.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSettings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-boolean channel routing​\u003c\/li\u003e\n\u003cli\u003eInput signal backup policy aimed to improve reliability against signal fault​\u003c\/li\u003e\n\u003cli\u003eSignal grouping for speaker routing​\u003c\/li\u003e\n\u003cli\u003eBuilt-in remote management via WiFi\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHardware monitor available for fast local diagnostics​\u003c\/li\u003e\n\u003cli\u003eLoad impedance measurement\/display for each channel​\u003c\/li\u003e\n\u003cli\u003eOutput power measurements\/display for each channel​\u003c\/li\u003e\n\u003cli\u003eMains voltage and current measurements\/display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Signal Processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTI C6000 DSP platform architecture​\u003c\/li\u003e\n\u003cli\u003eAD\/DA converter: dual 24bit @48 kHz Tandem® architecture, 127 dB dynamic range, per channel​\u003c\/li\u003e\n\u003cli\u003eInput\/output independent equalizers per channel providing Raised-cosine, custom FIR, parametric IIR: peaking, hi\/lo-shelving, all-pass, band-pass, band-stop, hi\/lo-pass​\u003c\/li\u003e\n\u003cli\u003eCrossovers: linear phase (FIR), hybrid (FIR-IIR), Butterworth, Linkwitz-Riley, Bessel: 6 dB\/oct to 48 dB\/oct (IIR)​\u003c\/li\u003e\n\u003cli\u003eInput delay up to 2s and output delay up to 100ms for time alignment per channel​\u003c\/li\u003e\n\u003cli\u003eActive DampingControl™ for cable compensation​\u003c\/li\u003e\n\u003cli\u003ePower limiter (TruePower™, RMS voltage, RMS current) + Peak Limiter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRemote management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl and monitoring through ArmoníaPlus​\u003c\/li\u003e\n\u003cli\u003eDedicated Web App\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable id=\"rack-specifications-table\" border=\"b\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_lv\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"second_lv first-row\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eOutput power per channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv\"\u003e\n\u003ctd\u003eOutput power per channel\u003c\/td\u003e\n\u003ctd\u003e5200 W @ 2 Ω\u003c\/td\u003e\n\u003ctd\u003e3000 W @ 4 Ω\u003c\/td\u003e\n\u003ctd\u003e1600 W @ 8 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv last-row\"\u003e\n\u003ctd\u003eBridge mode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10400 W @ 4 Ω\u003c\/td\u003e\n\u003ctd\u003e6000 W @ 8 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"second_lv\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eMax output voltage \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv\"\u003e\n\u003ctd\u003eMax unclipped output voltage @8 Ω\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e175 Vpeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv last-row\"\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e130 Apeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"first_lv\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eAC main power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv first-row\"\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eUniversal, regulated switch mode with PFC (Power Factor Correction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv\"\u003e\n\u003ctd\u003eNominal power requirement\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 – 240 V @ 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv\"\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e90 V – 264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"second_lv\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv last-row\"\u003e\n\u003ctd\u003eIdle\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv\"\u003e\n\u003ctd\u003eMax\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"first_lv\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eTHERMAL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv first-row\"\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0° – 45° C – 32° – 113° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"second_lv\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eThermal dissipation*\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv\"\u003e\n\u003ctd\u003e1\/8 of max output power @ 8 Ω\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e115 V:\u003c\/strong\u003e 2117 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e230 V:\u003c\/strong\u003e 1946 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"third_lv last-row\"\u003e\n\u003ctd\u003e1\/4 of max output power @ 8 Ω\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e115 V:\u003c\/strong\u003e 3892 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e230 V:\u003c\/strong\u003e 2875 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Powersoft","offers":[{"title":"Default Title","offer_id":43895014064171,"sku":"PS-PF000329","price":11703.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/3019\/5243\/files\/X8_gallery-cardL_front__99941.1771507503.1280.1280.png?v=1775691856","url":"https:\/\/www.empirepro.com\/products\/powersoft-x8-dsp-eth","provider":"Empire Pro","version":"1.0","type":"link"}